Background Cardiac implantable electronic device (CIED) infection is a major complication that is associated with increased morbidity and mortality. Recent data suggested a relationship between the antiseptic agent used for skin preparation at time of CIED procedure and risk for infection. Methods On April 30, 2011, we changed the antiseptic agent used for skin preparation at our tertiary care facility from chlorhexidine-alcohol to povidone-iodine for all CIED procedures. We retrospectively reviewed records of all patients who underwent CIED procedure 1 year before and after the change. CIED infection was defined as pocket or endovascular systemic infection that required removal within 1 year of the index procedure. We examined if the change affected the risk of CIED infection. Results A total of 2,792 patients underwent 2,840 CIED procedures; 1,748 (61.5%) had implantable cardioverter defibrillator procedures and 1,092 (38.4%) had permanent pacemaker procedures. Chlorhexidine-alcohol agent was used in 1,450 (51.1%) procedures, and povidone-iodine agent was used in 1,390 (48.9%). After 1 year of follow-up, 31 patients (1.09%) developed CIED infection that required system removal. The 1-year infection rate was 1.1% among both antiseptic agent groups and there were no significant differences in the infection presentations among both groups (P = 0.950). Multivariate Cox proportional hazards regression model showed that risk factors for infection within 1 year included age, diabetes, and African American race. Conclusion In one large cohort of patients undergoing CIED procedures, the antiseptic agent used for skin preparation (chlorhexidine-alcohol vs povidone-iodine) was not associated with increased risk of developing CIED infection. [ABSTRACT FROM AUTHOR]
Copyright of Pacing & Clinical Electrophysiology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Titel: |
The Impact of Changing Antiseptic Skin Preparation Agent used for Cardiac Implantable Electronic Device (CIED) Procedures on the Risk of Infection.
|
---|---|
Autor/in / Beteiligte Person: | QINTAR, MOHAMMED ; ZARDKOOHI, OMEED ; HAMMADAH, MUHAMMAD ; HSU, AMY ; WAZNI, OUSSAMA ; WILKOFF, BRUCE L. ; TARAKJI, KHALDOUN G. |
Link: | |
Zeitschrift: | Pacing & Clinical Electrophysiology, Jg. 38 (2015-02-01), Heft 2, S. 240-246 |
Veröffentlichung: | 2015 |
Medientyp: | academicJournal |
ISSN: | 0147-8389 (print) |
DOI: | 10.1111/pace.12514 |
Schlagwort: |
|
Sonstiges: |
|