A 20-year follow-up evaluation of total hip arthroplasty in patients younger than 50 using a custom cementless stem.
In: Hip International, Jg. 29 (2019-09-01), Heft 5, S. 481-488
Online
academicJournal
Zugriff:
Aim: The purpose of this study is to report the 20-year follow-up of a continuous series of 232 total hip arthroplasties (THAs) performed in patients aged less than 50 at the index surgery. Patients and methods: This is a retrospective monocentric study which reports the clinical, radiographical and survival results of 232 THAs performed with a custom cementless femoral stem in 212 patients evaluated at follow-up ranging from 14 to 27 years. Results: At the time of follow-up, the mean Harris Hip Score was 94.1 (range 48–100). The Hip disability and Osteoarthritis Outcome Score was >80 points in all 5 categories for 146 patients (68.9%). 18 hips (8.5%) showed radiographical femoral abnormalities. 23 hips (10.8%) underwent revision of the implants. 13 were isolated cup revisions. 3 more hips had bipolar revisions for aseptic loosening at 15, 20 and 21 years. Taking stem revision for aseptic loosening as an endpoint, survivorship was 96.8% at 20 years (95% confidence interval, 95.1–98.5; patients at risk 76) and 94.5% at 25 years (91.7–97.3; patients at risk 12). Conclusions: The results of this study confirm that THA using this custom-designed stem can provide excellent clinical and radiographical outcomes at a mean follow-up of 20 years in patients younger than 50. The individual 3D femoral stem and prosthetic neck has been able to restore extra- and intramedullary functional anatomy in this young and active cohort of patients. [ABSTRACT FROM AUTHOR]
Copyright of Hip International is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Titel: |
A 20-year follow-up evaluation of total hip arthroplasty in patients younger than 50 using a custom cementless stem.
|
---|---|
Autor/in / Beteiligte Person: | Dessyn, Edouard ; Flecher, Xavier ; Parratte, Sebastien ; Ollivier, Matthieu ; Argenson, Jean-Noël |
Link: | |
Zeitschrift: | Hip International, Jg. 29 (2019-09-01), Heft 5, S. 481-488 |
Veröffentlichung: | 2019 |
Medientyp: | academicJournal |
ISSN: | 1120-7000 (print) |
DOI: | 10.1177/1120700018803290 |
Schlagwort: |
|
Sonstiges: |
|