คุณลักษณะของการส่งถ่ายยาแบบไร้เข็มโดยใช้วิธีการกระแทก (Thai)
In: Journal of Science & Technology MSU, Jg. 43 (2024-03-01), Heft 2, S. 152-159
academicJournal
Zugriff:
At present, animal drug delivery using an injection device is a process involving a pressing force from a syringe directed through a syringe needle into the subcutaneous layer. However, there are disadvantages for drug action efficiency and time consuming injection. Therefore, this research aims to study the feasibility of application of the animal injection device using a new concept involving a high speed liquid jet with impact driven method. It delivered a high speed liquid jet penetrating through the skin without the use of a needle. The volume of liquid in the nozzle was 2 ml in experiments to compare the characteristics using the driving object method (distance 0 mm) and impact driven method (impact distances are 5, 7, 9, 11, 13, 15 and 17 mm). The characteristics such as, impact force of power source, average jet velocity, impact pressure of the jet, jet power and the behavior of jet were examined using a high-speed video camera. The results showed that, the impact distance increased, the impact force value of the power source increased, which an impact distance of 17 mm gave a maximum impact force of 475 N. The average velocity and the impact pressure of the jet are compared. An impact distance of 11 mm gave the maximum value of the average velocity and the impact pressure of jet to be 62 m/s and 2.28 MPa, respectively. Subsequently, the values of the impact distance were reduced to 13, 15 and 17 mm. The impact jet pressure value of the driving object method (distance 0 mm), and the level of impact jet pressure values was lower than the standard value such that it could not penetrate through the skin. Impact distances of 5, 7, 9, 11,13, 15 and 17 mm provided a high enough impact jet pressure to penetrate the skin. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Science & Technology MSU is the property of Mahasarakham University and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Titel: |
คุณลักษณะของการส่งถ่ายยาแบบไร้เข็มโดยใช้วิธีการกระแทก (Thai)
|
---|---|
Autor/in / Beteiligte Person: | มุขดา, ปรัชญา |
Zeitschrift: | Journal of Science & Technology MSU, Jg. 43 (2024-03-01), Heft 2, S. 152-159 |
Veröffentlichung: | 2024 |
Medientyp: | academicJournal |
ISSN: | 1686-9664 (print) |
Sonstiges: |
|