Wavelet threshold based TDL and TDR algorithms for real-time ECG signal compression.
In: Biomedical Signal Processing & Control, Jg. 3 (2008), Heft 1, S. 44-66
academicJournal
Zugriff:
Abstract: In this paper, two novel and simple, target distortion level (TDL) and target data rate (TDR), Wavelet threshold based ECG compression algorithms are proposed for real-time applications. The issues on the use of objective error measures, such as percentage root mean square difference (PRD) and root mean square error (RMSE) as a quality measures, in quality controlled/guranteed algorithm are investigated with different sets of experiments. For the proposed TDL and TDR algorithm, data rate variability and reconstructed signal quality is evaluated under different ECG signal test conditions. Experimental results show that the TDR algorithm achieves the required compression data rate to meet the demands of wire/wireless link while the TDL algorithm does not. The compression performance is assessed in terms of number of iterations required to achieve convergence and accuracy, reconstructed signal quality and coding delay. The reconstructed signal quality is evaluated by correct diagnosis (CD) test through visual inspection. Three sets of ECG data from three different databases, the MIT-BIH Arrhythmia (mita) ( Hz, 11b/sample), the Creighton University Ventricular Tachyarrhythmia (cuvt) ( Hz, 12b/sample) and the MIT-BIH Supraventricular Arrhythmia (mitsva) ( Hz, 10b/sample), are used for this work. For each set of ECG data, the compression ratio (CR) range is defined. The CD value of 100% is achieved for CR 12, CR 8 and CR 4 for data from mita, cuvt and mitsva databases, respectively. The experimental results demonstrate that the proposed TDR algorithm is suitable for real-time applications. [Copyright &y& Elsevier]
Copyright of Biomedical Signal Processing & Control is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Titel: |
Wavelet threshold based TDL and TDR algorithms for real-time ECG signal compression.
|
---|---|
Autor/in / Beteiligte Person: | Manikandan, M.S. ; Dandapat, S. |
Zeitschrift: | Biomedical Signal Processing & Control, Jg. 3 (2008), Heft 1, S. 44-66 |
Veröffentlichung: | 2008 |
Medientyp: | academicJournal |
ISSN: | 1746-8094 (print) |
DOI: | 10.1016/j.bspc.2007.09.003 |
Schlagwort: |
|
Sonstiges: |
|